Error · Spatial structure

How to fix Spatial hierarchy
in IFC files

Ensure the spatial structure follows Project ▸ Site ▸ Building ▸ Storey. Fix it in the authoring tool’s project setup before export.

Check your IFC file — free No account · No upload · Runs in your browser · 38 validation checks

The Spatial hierarchy check

Spatial structure not rooted in IfcProject

Category
Spatial structure
Standard
IFC schema
Severity
Error
Auto-fix
In authoring tool

How to fix Spatial hierarchy in your authoring tool

Concrete, tool-specific steps. The check itself is schema-agnostic and works for IFC2x3, IFC4, IFC4x1 and IFC4x3.

Authoring toolHow to fix
Revit Revit builds this hierarchy automatically from Project ▸ Site ▸ Building ▸ Levels. A broken hierarchy usually means missing Levels or a custom export — verify Levels exist and use the default IFC site/building assignment.
ArchiCAD Check the hierarchy in the IFC Translator and Story Settings: stories under the building, building under the site.
Tekla Configure the full spatial hierarchy (project/site/building/storey) in the IFC export dialog so it is complete and correctly ordered.
Allplan Define the full building structure (project/site/building/storey) in the structure palette before exporting.

Find and fix it in the browser

The whole flow runs client-side — your IFC file never leaves your machine.

01
Open your IFC file
Open IFC Viewer Online and drag & drop your IFC file. It is parsed locally in your browser via WebAssembly — nothing is uploaded.
02
Run the Health Score validation
Run validation. The "Spatial hierarchy" check (RULE_SPATIAL_HIERARCHY) flags every affected element and pinpoints it in the model tree.
03
Fix in Revit
Revit builds this hierarchy automatically from Project ▸ Site ▸ Building ▸ Levels. A broken hierarchy usually means missing Levels or a custom…
04
Fix in ArchiCAD
Check the hierarchy in the IFC Translator and Story Settings: stories under the building, building under the site.
05
Fix in Tekla
Configure the full spatial hierarchy (project/site/building/storey) in the IFC export dialog so it is complete and correctly ordered.
06
Fix in Allplan
Define the full building structure (project/site/building/storey) in the structure palette before exporting.
07
Re-validate
Re-export from your authoring tool and re-run validation to confirm the issue is resolved and your Health Score improved.

Check your whole model, not just one rule.

Spatial hierarchy is 1 of 38 checks. Run the full IFC Health Score to see every issue and a single 0–100 number — free, no account, no upload.